Short answer. A converter makes DC from shore power. An inverter makes AC from batteries. An inverter charger does both and is usually misconfigured rather than broken. OCRV Center diagnoses, reconfigures and replaces Magnum, Xantrex, Victron, WFCO and Progressive Dynamics units in shop in Yorba Linda for West Covina owners.

OCRV Center works in shop at 23281 La Palma Ave in Yorba Linda, about 22 miles and 30 to 45 minutes from West Covina.

Request a quote

Tell us about the vehicle and the damage. Insurance walk ins are welcome.

Bring it in if

Symptoms that point to this repair

If you recognize two or more of these, the vehicle is worth putting on a lift before the damage spreads.

Coach runs fine on shore power for hours then everything 12 volt fades at once

Inverter clicks on and off repeatedly in search mode with nothing plugged in

Cooling fan in the converter compartment runs constantly or never runs

Inverter shuts down under a load it used to carry without trouble

Charger never brings the bank to full no matter how long it stays plugged in

Error code on the remote panel that clears itself and returns

Buzzing or humming from the converter bay that was not there before

Microwave or coffee maker trips the inverter instantly on battery power

Which box do you actually have

Troubleshooting starts by identifying the arrangement, because three different configurations produce nearly identical symptoms. The first is a plain converter, common in trailers and fifth wheels, built into the same enclosure as the breaker and fuse panel. WFCO and Progressive Dynamics dominate here. It makes DC from shore power and does nothing else.

The second is a plain converter plus a separate standalone inverter, which is what most owner added inverters look like. The inverter feeds a few receptacles or a small subpanel and charges nothing. Owners with this arrangement often believe the inverter is charging their batteries, and when the converter fails they blame the inverter.

The third is an inverter charger: one unit doing both jobs, usually a Magnum, a Xantrex or a Victron, found on diesel pushers, higher end fifth wheels and serious van conversions. These are configurable devices with remote panels, chemistry settings, charge current limits, transfer relays and load support behavior. Most of them come to us working correctly and set incorrectly.

The distinction changes the diagnosis completely. On a plain converter coach, a dead bank in the morning after a night on shore power means the converter. On an inverter charger coach, the same symptom might mean a charge current limit set to almost nothing, a chemistry profile that never reaches lithium absorption voltage, or a transfer relay that never closed to accept shore power in the first place.

How converters fail and what the failure looks like

Converters rarely die all at once. The most common progression is a gradual loss of output capacity. Electrolytic capacitors dry out with heat and age, output ripple rises, current capacity falls, and the unit ends up producing a fraction of its rating while still showing an output voltage on a meter. The coach runs on shore power because the batteries silently carry the shortfall, and then everything DC goes down together when the bank finally empties.

Cooling is the other failure. Most converters have a thermostatically controlled fan and a compartment that was designed with airflow in mind. Owners store gear in that bay, the airflow stops, the unit runs hot, capacitor life collapses, and the failure arrives years early. A fan that has seized or filled with dust does the same thing. When we replace a converter we always look at why the last one died.

Older single stage converters fail in a different direction. They output one fixed voltage forever with no float stage, which is fine for a weekend and destructive across a winter on shore power. Flooded batteries boil dry. AGM batteries lose water they cannot replace. Replacing an ancient single stage unit with a multistage converter is often the highest value repair on an older trailer.

The last one is deceptive: a converter that works perfectly while the connection between it and the battery does not. A corroded lug or an undersized cable will show correct voltage at the converter output and inadequate voltage at the battery terminals. We measure at the battery, always, because that is the only place the number means anything.

Inverter faults: search mode, surge and waveform

Search mode, sometimes called power save, is the first source of confusion. The inverter shuts its output down and pulses periodically to see whether a load has appeared, which saves standby current. Small loads below the search threshold never wake it, so a phone charger or an LED lamp appears to be plugged into a dead outlet. The clicking that owners report is the inverter searching, not failing.

Surge capacity is the second. Motors and compressors draw several times their running current at startup. An inverter rated well above a load's running watts can still shut down on that startup surge, which is why a microwave or a coffee maker trips an inverter that runs a television all day. Inverters are specified with both a continuous rating and a surge rating, and the surge rating is what decides whether an appliance will actually start.

Waveform matters for certain loads. A modified sine inverter produces a stepped approximation that most resistive loads tolerate. Devices with motors, variable speed controls, sensitive electronics, some medical equipment and many modern appliances either run hot, buzz audibly or refuse to operate. Pure sine costs more and is the right answer on any coach running a residential refrigerator, a variable speed tool or instrument loads.

Cable and fusing on the DC side is where installs go wrong. An inverter producing sustained AC pulls enormous DC current, and cable sized by guess rather than by run length and load will drop voltage until the inverter shuts down on low input while the battery bank is actually fine. Fusing has to be at the battery end, sized for the cable, in a device rated to interrupt the fault current a large bank can deliver.

  • Search mode looks like a failure and is a setting
  • Surge rating, not continuous rating, decides whether a motor load starts
  • Modified sine causes buzzing, heat and refusals on motor and electronic loads
  • Undersized DC cable shuts an inverter down on a healthy battery bank
  • Battery end fusing must be rated for the fault current the bank can supply

Configuration on Magnum, Xantrex and Victron units

Inverter chargers are computers with power electronics attached, and their settings decide almost everything about how the coach behaves. Battery type is the setting that does the most damage when it is wrong. A Magnum set to flooded on an AGM bank overcharges it every cycle. A Xantrex set for AGM on a lithium bank never reaches the absorption voltage lithium wants, and the owner concludes the expensive new batteries are defective.

Charge current limit is the second. These units allow the charger output to be capped, usually so a small shore connection is not overwhelmed. Set too low, the charger trickles and the bank never fills. We find units limited to a small fraction of their capability because someone once needed to run on a fifteen amp household outlet and never changed it back.

Transfer and load support settings decide how the unit behaves when shore power is marginal. Load support lets the inverter contribute from the battery when incoming shore power is not enough to carry the load. Configured well it is elegant. Configured badly it drains the bank while the coach sits plugged in, which owners experience as batteries that die on shore power.

Victron systems add a network layer where devices coordinate charging. When the network is configured correctly the solar controller, the inverter charger and the battery management system agree on a single target. When it is not, the solar controller and the inverter charger fight each other, and the visible symptom is charging current that appears and disappears with no obvious cause. Reading the configuration is the first thing we do, not the last.

Replacement, sizing and installation standards

When a unit does need replacing, sizing starts with what the coach must run on battery rather than with the largest number that fits the budget. A bigger inverter draws more standby current, demands larger cable and a larger bank, and generates more heat in a bay that may not be ready for it. We size to the actual load list, including surge, and then confirm the battery bank can actually support that load for a useful length of time.

Mounting and ventilation are part of the specification. These units dissipate real heat and need clear airflow, and installing one in a sealed bay is how a two year old inverter dies. On lithium systems we also confirm the charger profile is programmable to the battery manufacturer's targets before choosing the unit, because a fixed profile charger and a lithium bank is a mismatch that cannot be corrected later.

We also correct previous installs regularly: inverters bonded neutral to ground internally while shore power is bonded upstream, which trips every modern campground ground fault device. Output wired into the main panel with no transfer arrangement, which back feeds the shore inlet. Undersized DC cable. Missing battery end fusing. Each of those is a real safety problem and each one is common.

Everything happens in shop at 23281 La Palma Ave in Yorba Linda. We do not offer mobile service. From West Covina it is about 22 miles: the 10 or the 60 west to the 57 south, then the 91 east to Imperial Highway, with Carbon Canyon Road over to the 71 as the afternoon shortcut. Call (949) 799-3387 to schedule.

Questions we get asked

What is the difference between my converter and my inverter

A converter takes 120 volt shore power and makes 12 volt DC to run the house and charge the batteries. An inverter does the opposite, taking battery DC and making 120 volt AC for selected circuits when no shore power is connected. A standalone inverter charges nothing. An inverter charger is one box doing both jobs. Knowing which arrangement your coach has changes the diagnosis completely, and it is the first thing we identify.

Why does my inverter click on and off when nothing is running

That is search mode, also called power save. To reduce standby drain, the inverter drops its output and pulses periodically to check whether a load has appeared. Loads smaller than the search threshold, like a phone charger or a single LED lamp, never wake it, so the outlet appears dead. It is a setting, not a fault. We can disable search mode at the cost of a slightly higher continuous draw from the bank.

My inverter is rated well above my microwave. Why does it shut off

Because the number that matters at startup is the surge rating, not the continuous rating. Motors and magnetrons draw several times their running current for a moment when they start. Undersized DC cable makes it worse, since a long or thin cable drops enough voltage during the surge that the inverter faults on low input while the battery bank is perfectly healthy. We check cable sizing and surge rating together.

My new batteries never reach full charge. Is the charger broken

Usually not. On inverter chargers the two most common causes are a battery type setting that does not match the installed chemistry and a charge current limit left at a low value from a time when the coach was on a small household outlet. Neither throws a fault. We read the configuration first, then measure charge voltage and current at the battery terminals rather than at the unit, since cable losses hide a lot.

Can you replace an old single stage converter with a modern one

Yes, and on an older trailer it is often the highest value repair available. A single stage unit outputs one fixed voltage forever with no float stage, which cooks flooded batteries over a winter on shore power and permanently dries out AGM. A multistage replacement moves through bulk, absorption and float and drops to a storage level when full. We also check why the old one died, since blocked bay airflow shortens converter life dramatically.